Banner image
WITHDRAWN - Radon: guidance on protective measures for new buildings (including supplementary advice for extensions, conversions and refurbishment) (2007 ed)<br><b>PDF Download (10MB)</b>

WITHDRAWN - Radon: guidance on protective measures for new buildings (including supplementary advice for extensions, conversions and refurbishment) (2007 ed)
PDF Download (10MB)

by Chris Scivyer (26-Nov-2007)

£30.00

Sorry, this item is not available

Book Description

WITHDRAWN - Superseded by 2015 edition

This guide, which supports Building Regulations Approved Document L, offers practical guidance for reducing the concentration of radon in new buildings, extensions, conversions, and refurbishment projects. It has been prepared to help architects, designers, builders, and installers specify and install successful protective measures in order to reduce the risk to occupants of exposure to radon, which can cause lung cancer. The guide contains maps of England and Wales for identifying areas where radon protective measures should be installed. This 2007 edition of the report replaces guidance published in 1999.

• New maps with additional detail such as towns and road networks to help readers identify radon affected areas more easily.
• Additional drawings and photographs
• Additional guidance on protective measures suitable for new non-domestic buildings and extensions
• New guidance on protective measures for conversion and refurbishment projects and for suspended timber ground floor.

Pages: 53

Contents

  • Introduction
  • What is radon?

 

  • Protective measures
  • Determining the level of protection
  • Protective measures: technical approach
    • Basic radon protection
    • Full radon protection
  • Detailed protective measure
    • Workmanship and inspection
    • Radon-proof barriers
    • Protecting suspended timber floors
    • Tanking to basements and cellars
    • High water-table
    • Slip or shear planes
    • Blinding
    • Reinforced slabs
    • Accessible thresholds
    • Condensation and cold bridges
    • Subfloor ventilation
    • Subfloor depressurisation and sumps
    • Garages
    • Extensions
    • Conversions and refurbishment
    • Monitoring of completed buildings and extensions
  • Stepped foundations: additional points to consider
  • Acknowledgements
  • References and Further reading
  • Annex A: 20 maps of areas where basic or full protection should be provided You may also be interested in BRE’s
    Buying homes in radon-affected areas

 

Customers who bought this title also bought

Construction of new buildings on gas-contaminated land (Scanned copy)
Radon protection for new large buildings (GG 75 revised) DOWNLOAD
A protocol for the assessment of indoor air quality in homes and office buildings Downloadable version